Skip to main content

MasterLine 10 Hidden Vent

Technical information

Performance

Insulation

Thermal insulation (Best) - Uf
0.94 W/m²K
Thermal insulation - Uw
0.78 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, warm edge spacer, @1.23x1.48m (114mm sight line), 45mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E900 (900Pa)
Wind load resistance
Class C5 (2000Pa)
Acoustics - Rw(C;Ctr)
47(-1;-3) dB
Durability
Class 3 (20000 cycles)

Safety & Security

Burglar resistance
RC2
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Sightlines

Min. frame width (inward opening)
87 mm
Min. vent width (inward opening)
0 mm
Min. frame-vent width (inward opening)
87 mm
Depth frame
97 mm
Depth Vent
107 mm
Depth frame-vent
107 mm

Glazing

Rebate height
7.5 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
Min. glass thickness - vent
45 mm
Max. glass thickness - vent
77 mm