ConceptWall 60
Technical informationPerformance
Energy
- Thermal insulation - Uf
- 0.8 W/m²K
Comfort
- Air tightness
- AE 1200 (1200Pa)
- Water tightness
- Class E1200 (1200Pa)
- Wind load resistance
- E2400 (2400Pa)
- Acoustics - Rw(C;Ctr)
- 47(-2;-5) dB
Safety
- Burglar resistance
- RC2 WK2 RC3 WK3
- Impact resistance
- I5/E5
Properties
Max. dimensions & weight
- Min. height of vent
- 600 mm
- Max. height of vent
- 2000 mm
- Min. width of vent
- 450 mm
- Max. width of vent
- 2500 mm
- Max. weight of vent
- 180 kg
- Max. weight of glass
- 700 kg
- Min. intertia mullion - Ix
- 44.6 mm
- Max. intertia transom - Ix
- 632 mm
- Min. intertia transom - Iy (glass load)
- 32.8 mm
- Max. intertia transom - Iy (glass load)
- 89 mm
Sightlines
- Min. visible width (interior view)
- 60 mm
- Min. visible width (exterior view)
- 60 mm
- Min. depth mullion
- 62.5 mm
- Max. depth mullion
- 251.5 mm
- Min. depth transom
- 67.2 mm
- Max. depth transom
- 268 mm
- Min. roof inclination - standard
- 75 degrees
- Max. roof inclination - standard
- 105 degrees
Glazing
- Rebate height
- 25 mm
- Glazing method
- Dry glazing External glazing Pressure plate glazing Structural Glued Glazing Structural clamped glazing Structural Glued Stepped Glazing
- Min. glass thickness - frame/element
- 6 mm
- Max. glass thickness - frame/element
- 62 mm
- Min. glass thickness - vent
- 24 mm
- Max. glass thickness - vent
- 62 mm