Skip to main content

ConceptWall 50 High Insulation

Technical information

Performance

Insulation

Thermal insulation (Best) - Uf
0.56 W/m²K

Comfort

Air tightness
AE 1950 (1950Pa)
Water tightness
RE1950 (1950Pa)
Wind load resistance
E2400 (2400Pa)
Acoustics - Rw(C;Ctr)
47(-2;-5) dB

Safety & Security

Burglar resistance
RC2 - RC3
Impact resistance
I5/E5
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. intertia mullion - Ix
14 cm4
Max. intertia mullion - Ix
2690 cm4
Min. intertia transom - Ix
4 cm4
Max. intertia transom - Ix
552 cm4
Min. intertia transom - Iy (glass load)
8 cm4
Max. intertia transom - Iy (glass load)
57 cm4

Sightlines

Min. width transom profile
50 mm
Min. visible width (interior view)
50 mm
Min. visible width (exterior view)
50 mm
Min. depth mullion
42 mm
Max. depth mullion
300 mm
Min. depth transom
5 mm

Glazing

Glazing method
Dry glazing - External glazing - Pressure plate glazing - Structural Glued Glazing - Structural clamped glazing
Min. glass thickness - frame/element
22 mm
Max. glass thickness - frame/element
60 mm