Performance

Insulation

Thermal insulation (Best) - Uf
0.89 W/m²K
Uw Dependencies
Single inward opening door: Ug 0.6W/m²K, warm edge spacer, @1.23x2.18m, 48mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class 9A (600Pa)
Wind load resistance
Class C3 (1200Pa)
Acoustics - Rw(C;Ctr)
40 (-1;-5) dB
Durability
Class 8 (1000000 cycles)
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Max. height of vent
3000 mm
Min. width of vent
500 mm
Max. width of vent
1400 mm
Max. weight of vent
250 kg
Max. weight of glass
1200 kg

Sightlines

Min. frame width (inward opening)
83.5 mm
Min. vent width (inward opening)
71.5 mm
Min. frame-vent width (inward opening)
162 mm
Min. frame width (outward opening)
27 mm
Min. vent width (outward opening)
110.5 mm
Min. frame-vent width (outward opening)
162 mm
Min. width transom profile
87 mm
Min. height threshold
0 mm
Depth frame
97 mm
Depth Vent
97 mm
Depth frame-vent
97 mm
Max. depth transom
97 mm

Glazing

Rebate height
27 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
Min. glass thickness - frame/element
20 mm
Max. glass thickness - frame/element
78 mm
Min. glass thickness - vent
20 mm
Max. glass thickness - vent
78 mm