Skip to main content

MasterLine 10 Anti Panic Door

Technical information

Performance

Insulation

Thermal insulation (Best) - Uf
0.98 W/m²K
Uw Dependencies
Single outward opening door: Ug 0.6W/m²K, warm edge spacer, @1.23x2.18m, 162mm sight line & 36mm glass
Thermal insulation - Ud
0.81 W/m²K

Comfort

Acoustics - Rw(C;Ctr)
40(-1;-3) dB
Durability
Class 8 (1000000 cycles)

Safety & Security

Burglar resistance
RC2
Impact resistance
I5 - E5
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Max. height of vent
3000 mm
Max. width of vent
1400 mm
Max. weight of vent
250 kg

Sightlines

Min. frame width (outward opening)
44.5 mm
Min. vent width (outward opening)
110.5 mm
Min. frame-vent width (outward opening)
162 mm