FlameLine
Technical informationPerformance
Insulation
- Uw Dependencies
- 1.23x2.18m, Ug 0.5, psi 0.03
- Thermal insulation - Ud
- 1.2 W/m²K
Comfort
- Air tightness
- Class 3 (600Pa)
- Water tightness
- Class E900 (900Pa)
- Wind load resistance
- Class C4 (1600Pa)
- Acoustics - Rw(C;Ctr)
- 43(-1;-3) dB
Safety & Security
- Burglar resistance
- RC2
- Fire resistance
- EI 30 - EI 60 - EI₁ 30 - EI₁ 60 - EI₂ 30 - EI₂ 60
Properties
Max. dimensions & weight
- Max. height of vent
- 3000 mm
- Max. width of vent
- 1200 mm
- Max. weight of vent
- 250 kg
Sightlines
- Min. frame width (inward opening)
- 74 mm
- Min. vent width (inward opening)
- 74.5 mm
- Min. frame-vent width (inward opening)
- 154.5 mm
- Min. frame width (outward opening)
- 48 mm
- Min. vent width (outward opening)
- 100.5 mm
- Min. frame-vent width (outward opening)
- 154.5 mm
- Min. width transom profile
- 106 mm
- Depth frame
- 85 mm
- Depth Vent
- 85 mm
- Depth frame-vent
- 85 mm