Skip to main content

FlameLine Insulated Glass

Technical information

Performance

Insulation

Thermal insulation (Most Common) - Uf
2.2 W/m²K
Thermal insulation - Ud
1.4 W/m²K

Comfort

Air tightness
Class 3 (600Pa)
Water tightness
Class E900 (900Pa)
Wind load resistance
Class C4 (1600Pa)
Acoustics - Rw(C;Ctr)
43(-1;-3) dB

Safety & Security

Burglar resistance
RC2
Fire resistance
EI₁ 30 - EI₁ 60 - EI₂ 30 - EI₂ 60 - EI 30 - EI 60
Operating Forces Class
Class 1
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Max. weight of vent
250 kg
Max. weight of fixed vent
400 kg

Sightlines

Min. frame width (inward opening)
74 mm
Min. vent width (inward opening)
74.5 mm
Min. frame-vent width (inward opening)
154.5 mm
Min. vent-vent width (inward opening)
181 mm
Min. frame width (outward opening)
48 mm
Min. vent width (outward opening)
100.5 mm
Min. frame-vent width (outward opening)
154.5 mm
Min. vent-vent width (outward opening)
181 mm
Min. width transom profile
106 mm
Min. height threshold
18 mm
Depth frame
85 mm
Depth Vent
85 mm
Depth frame-vent
85 mm

Glazing

Min. glass thickness - vent
25 mm
Max. glass thickness - vent
69 mm