Skip to main content

FlameLine Fixed Glazing

Technical information

Performance

Insulation

Uw Dependencies
1.48x2.18m, Ug 0.5, psi 0.03
Thermal insulation - Ud
0.83 W/m²K

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E1050 (1050Pa)
Wind load resistance
Class C4 (1600Pa)
Acoustics - Rw(C;Ctr)
42(-1;-2) dB

Safety & Security

Burglar resistance
RC2
Fire resistance
EI 60
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Max. weight of fixed vent
400 kg

Sightlines

Min. frame width (inward opening)
74 mm
Min. vent width (inward opening)
74.5 mm
Min. frame-vent width (inward opening)
154.5 mm
Min. frame width (outward opening)
48 mm
Min. vent width (outward opening)
100.5 mm
Min. frame-vent width (outward opening)
154.5 mm
Min. width transom profile
106 mm
Depth frame
85 mm
Depth Vent
85 mm
Depth frame-vent
85 mm