Skip to main content

FlameLine Exterior Fixed Glazing

Technical information

Performance

Insulation

Uw Dependencies
1.48x2.18m, Ug 0.5, psi 0.03
Thermal insulation - Ud
0.83 W/m²K

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E1050 (1050Pa)
Wind load resistance
Class C4 (1600Pa)
Acoustics - Rw(C;Ctr)
45(-2;-5) dB

Safety & Security

Burglar resistance
RC2
Fire resistance
EI 60 - EW 60
* Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent
4000 mm
Max. weight of fixed vent
400 kg

Sightlines

Min. frame width (inward opening)
74 mm
Min. vent width (inward opening)
74.5 mm
Min. frame-vent width (inward opening)
154.5 mm
Min. frame width (outward opening)
48 mm
Min. vent width (outward opening)
100.5 mm
Min. frame-vent width (outward opening)
154.5 mm
Min. width transom profile
106 mm
Depth frame
85 mm
Depth Vent
85 mm
Depth frame-vent
85 mm