ConceptSystem 77 Bulletproof
Technical informationPerformance
Insulation
- Thermal insulation (Best) - Uf
- 2.8 W/m²K
- Uw Dependencies
- Single door, with dimensions 1230*2180mm, Ug 1.1 W/m²K, psi 0.11, 36mm BR4-S IGU
- Thermal insulation - Ud
- 2.1 W/m²K
Safety & Security
- Bullet resistance
- FB4 - FSG - FB6 - Kalashnikov
Properties
Max. dimensions & weight
- Min. height of vent
- 500 mm
- Max. height of vent
- 3000 mm
- Min. width of vent
- 500 mm
- Max. width of vent
- 1400 mm
Sightlines
- Min. frame width (inward opening)
- 77 mm
- Min. vent width (inward opening)
- 77 mm
- Min. frame-vent width (inward opening)
- 154 mm
- Min. frame width (outward opening)
- 77 mm
- Min. vent width (outward opening)
- 102 mm
- Min. frame-vent width (outward opening)
- 179 mm
- Min. width transom profile
- 102 mm
- Min. height threshold
- 0 mm
- Depth frame
- 97 mm
- Depth Vent
- 97 mm
- Depth frame-vent
- 68 mm
Glazing
- Rebate height
- 25 mm
- Glazing method
- Dry glazing - Siliconized glazing - Internal glazing - Glazing bead